Abstract:
Nowadays, Repsol Chemistry Industrial Complex produces a wide assortment of oil products, among them monopropylene glicol, dipropylene glicol and tripropylene glicol. These compounds are produced in the reaction between processed water and propylene oxide. In order to control organic volatile compounds in water, some gas chromatography analysis are done. Moreover with GC analysis they can control the presence of contamination sources in a plant’s equipment. The goal of this project is the optimization of an existing gas chromatography method to determine volatile organic compounds in water samples from the glicols plant. Therefore, a new gas chromatography method has been developed without adding any standard intern in the pre-treatment sample. A second goal of this project is to validate the new method and compare the quality parameters with and without adding a standard intern. Moreover F-02, F-14, H-07 and H-08 samples were analysed using the new method with and without adding standard intern. The repeatability and intermediate precision results that were obtained show that it is not necessary to use a standard intern to determine volatile organic compounds in processed water samples by GC-FID. Moreover, it should also be mentioned that toluene, ethylbenzene and styrene have poor repeatability. Besides, the regressions obtained from toluene, ethylbenzene and styrene do not predict the concentration values of the mixed standards. If the calibration standards are carried out only by adding these compounds to water, good prediction values are obtained. This means that there is a matrix effect due to some interference in the prepared standards or aromatic compounds which are more soluble in an organic environment. The sum of the concentrations of DPG and TPG isomers in the samples does not correspond exactly to the concentrations of DPG and TPG as the regression lines have been built by distribution of areas. The predicted values of the samples without adding the internal standard conform to values calculated in the chemical plant. Finally good recoveries where achieved.
Project director:
Sendrós de la Fuente, Jacob
Work's codirector:
Borrull Ballarín, Francesc
Department:
Química Analítica i Química Orgànica
Education area(s):
Química
Entity:
Universitat Rovira i Virgili (URV)
TFG credits:
12
Creation date in repository:
2017-01-29
Work's public defense date:
2017-06-14
Academic year:
2016-2017
Confidenciality:
No
Subject areas:
Chemistry
Access rights:
info:eu-repo/semantics/openAccess
Title:
Determinació de compostos orgànics volàtils en aigües de procés mitjançant GC-FID
Type:
info:eu-repo/semantics/bachelorThesis
Contributor:
Borrull Ballarín, Francesc
Sendrós de la Fuente, Jacob
Subject:
Química
Chemistry
Química
Química
Date:
2017-06-14
Language:
cat
Creator:
Solsona Roca, Sergi
Rights:
info:eu-repo/semantics/openAccess
Search you record at:
Available files
File
Description
Format
Memòria
Memory
application/pdf
View/Open
Show entire record
Go back
Information
© 2011 Universitat Rovira i Virgili
Legal
Accessibility
Contact