Repositori institucional URV
Belongs to TFG:SerieGeneralQ collection
TITLE:
Determinació de l'SE-2 per cromatografia iònica - TFG:296
Handle:
https://hdl.handle.net/20.500.11797/TFG296
Student:
Estalella Rodríguez, Maria
Language:
cat
Title in original language:
Determinació de l'SE-2 per cromatografia iònica
Title in different languages:
SE-2 determination by ion chromatography
Keywords:
Ion chromatography, analytical method, validation
Subject:
Química
Abstract:
One of the main products is required to have its quality determinate since it is expected to be introduced to quality control programmes. Therefore, the aim of this project is to develop and validate not only a method that allows the determination of SE-2, sulphites and sulphates from Hostapon SI, which is an anionic surfactant, but also all of them at once. It has been carried out by ionic chromatography. The SE-2 is formed as a result of a secondary reaction in which the Hostapon SI reacts with a second mole of ethylene oxide. As far as sulphites are concerned, they are starting reagents that haven’t reacted, and the oxidation process of that results in the formation of sulphates. Since there was no chromatographic method for this equipment it was necessary to find the chromatographic conditions. Three separation columns and two types of mobile phase have been evaluated, carbonate/bicarbonate and NaOH, and it has been noted that the best option was 5mM NaOH. The flow of the mobile phase, the dilution of the sample and the temperature of the oven has been also optimised. Finally, the key to create a good separation of SE-2 has been to dilute the sample more. Once the chromatographic condition had been met, the next step was the validation. The limit of detection, the limit of quantification, the instrumental repeatability, the method repeatability, the reproducibility and the recuperation parameters have been evaluated. The obtained values have been acceptable except the reproducibility and the recuperation, something that could have been caused by some issues in the injection or integration problems. In order to improve the data obtained in the validation, the conditions should be optimised to obtain a more suitable separation and integration of the peaks.
Project director:
Massons Bosch, Jaume
Work's codirector:
Campos Carrasco, Ariadna
Department:
Química Analítica i Química Orgànica
Education area(s):
Química
Entity:
Universitat Rovira i Virgili (URV)
TFG credits:
12
Creation date in repository:
2015-10-15
Work's public defense date:
2015-06-08
Academic year:
2014-2015
Confidenciality:
No
Subject areas:
Chemistry
Access rights:
info:eu-repo/semantics/openAccess
Type:
info:eu-repo/semantics/bachelorThesis
Títol:
Determinació de l'SE-2 per cromatografia iònica
Contributor:
Campos Carrasco, Ariadna
Massons Bosch, Jaume
Subject:
Química
Chemistry
Química
Química
Date:
2015-06-08
Language:
cat
Creator:
Estalella Rodríguez, Maria
Rights:
info:eu-repo/semantics/openAccess
Search your record at:
Available files
File
Description
Format
Memòria
Memory
application/pdf
View/Open
Show entire record
Go back
All objects of this collection
Information
© 2011 Universitat Rovira i Virgili
Legal
Accessibility
Contact