GENERAL INFORMATION ------------------- 1. Dataset Title: Ceramic passive samplers with ion-exchange sorbent 2. Authorship: Author Name: Clivillé Cabré, Pol Author Affiliation: https://ror.org/00g5sqv46 Author Identifier Scheme: ORCID Author Identifier: https://orcid.org/0009-0005-4134-7697 Author Name: Marcé-Recasens, Rosa Maria Author Affiliation: https://ror.org/00g5sqv46 Author Identifier Scheme: ORCID Author Identifier: https://orcid.org/0000-0002-5667-2899 Author Name: Lacorte, Silvia Author Affiliation: https://ror.org/00g5sqv46 Author Identifier Scheme: ORCID Author Identifier: https://orcid.org/0000-0001-7192-4057 Author Name: Borrull, Francesc Author Affiliation: https://ror.org/00g5sqv46 Author Identifier Scheme: ORCID Author Identifier: https://orcid.org/0000-0003-1475-8122 3. Dataset contact: Dataset Contact Name: Fontanals Torroja, Núria Dataset Contact Affiliation: Universitat Rovira i Virgili Dataset Contact Email: nuria.fontanals@urv.cat DESCRIPTION ----------- 1. Language: English 2. Description Value: Evaluation of the different parameters involved in the calibration of the passive samplers using an ion-exchange sorbent. The parameters are (partition constant, difusion rate and sampling rate and were assayed in two samples: bottle water (1 file ) and river water (1 file). 3. Subject: Chemistry 4. Keywords: Keyword Value: sampling Keyword Vocabulary: DECS Keyword Value: ion exchange Keyword Vocabulary: decs 5. Notes Text: Constante de partición (K) Kd= Cs/Ceq Cs= concentración adsorbida a l'adsorbent en ng/g Ceq= concentración a la solució exterior ng/mL als 14 d ng= ng adsorbits al mostrejador al dia 13 SAMPLING RATE Sample rate= k/Cw = (De*A)/Δg Rs=k/Cw k= pendent de la recta ng adsorbits vs. temps (h) Cw= concentració en la solució exterior Diffusion coeficient (De) De= (K*Ag)/(Cw*As) K= pendiente Length (mm) en cm2 * s-1 g= gruix capa difusió (gruix de la paret ceràmica) External diameter (mm) Cw= concentració solució exterior Internal diameter (mm) As= area interna del cilindre =2*∏*r*h=d*∏*h Thickness (mm) Cw = (M*Δg)/(De*A*t) = M/(Rs*t) 6. Producer: Producer Name: Universitat Rovira i Virgili Producer Abbreviation: URV Producer URL: https://www.urv.cat 7. Grant information: Grant Number Agency: Ministerio de Ciencia e Innovación Grant Number Value: PID2020-114587GB-I00 8. Distributor: Distributor Name: Universitat Rovira i Virgili Distributor Abbreviation: URV Distributor URL: https://dataverse.csuc.cat/dataverse/URV 9. Depositor: Fontanals Torroja, Núria 10. Date of Deposit: 2025-05-13 11. Date of data collection (single date or date range): Date of Collection Start: 2022-04-01 Date of Collection End: 2022-07-30 12. Kind of Data: Experimental data ACCESS INFORMATION ------------------ 1. Creative Commons License of the dataset: CC BY 4.0 2. Dataset DOI: https://doi.org/10.34810/data2240 3. Related publication: Publication Relation Type: IsSupplementTo Publication Citation: CLIVILLÉ-CABRÉ, P.; LACORTE, S.; BORRULL, F.; FONTANALS, N.; MARCÉ, R.M. “Evaluation of ceramic passive samplers using a mixed mode strong cationic sorbent to monitor contaminants in river water” J. Chromatogr. A 1708 (2023) 464348 https://doi.org/10.1016/j.chroma.2023.464348 Publication ID Type: doi Publication ID Number: https://doi.org/10.1016/j.chroma.2023.464348 FILE OVERVIEW ------------- File name: Bottled water calibration_1.tab File format: text/tab-separated-values File name: River water calibration_1.tab File format: text/tab-separated-values