Repositori institucional URV
Español Català English
TÍTULO:
Changes in pH as a result of galvanic currents used in percutaneous needle electrolysis - imarina:9220501

Autor/es de la URV:Bosque Alberich, Marc / MARGALEF CATALÀ, RAMON / Santafé Martínez, Manuel
Autor según el artículo:Margalef, Ramón; Minaya-Muñoz, Francisco; Valera-Garrido, Fermín; Bosque, Marc; Santafé, Manel M.
Direcció de correo del autor:manuel.santafe@urv.cat
Identificador del autor:0000-0002-5462-5108
Año de publicación de la revista:2020
Tipo de publicación:Journal Publications
Referencia de l'ítem segons les normes APA:Margalef, Ramón; Minaya-Muñoz, Francisco; Valera-Garrido, Fermín; Bosque, Marc; Santafé, Manel M. (2020). Changes in pH as a result of galvanic currents used in percutaneous needle electrolysis. Revista Fisioterapia Invasiva / Journal Of Invasive Techniques In Physical Therapy, 03(01), 006-006. DOI: 10.1055/s-0040-1712511
Referencia al articulo segun fuente origial:Revista Fisioterapia Invasiva / Journal Of Invasive Techniques In Physical Therapy. 03 (01): 006-006
Resumen:Abstract Aim?To determine whether sodium chloride electrolysis causes a change in the pH of tissues. Methods?The effects of a 3?mA galvanic current has been evaluated, applied for 3?seconds and 3 repetitions (3:3:3). In vitro pH changes were evaluated in three experiments: 1) Eppendorf® tubes filled with Ringer's solution; 2) a very small volume of Ringer's solution (100µl); 3) Eppendorf® tubes filled with saline solution (NaCl 0.9%). The pH changes in the gastrocnemius of mice were evaluated, using the left limb as a control and the right limb for the intervention. The gastrocnemius muscles were ground up and the pH of each group was determined. Results?In the in vitro experiments 1 and 2, no variation was observed in the pH of either the cathode in the Ringer's solution or the anode in the Ringer's solution (the variation did not exceed 16% in either of the cases, p> 0.05). In the third in vitro study, the pH after galvanic current application increased by 70% in the saline solution of the cathode and the anode pH decreased by 34% (p? Conclusions?The galvanic current used in percutaneous needle electrolysis applying the 3:3:3 parameters generates very small changes in the pH, in the area near the needle, which the body is able to rapidly compensate for.
DOI del artículo:10.1055/s-0040-1712511
Enlace a la fuente original:https://www.thieme-connect.com/products/ejournals/abstract/10.1055/s-0040-1712511
Versión del articulo depositado:info:eu-repo/semantics/publishedVersion
Acceso a la licencia de uso:https://creativecommons.org/licenses/by/3.0/es/
Departamento:Psicologia
Ciències Mèdiques Bàsiques
URL Documento de licencia:https://repositori.urv.cat/ca/proteccio-de-dades/
Palabras clave:Clean water and sanitation
Entidad:Universitat Rovira i Virgili
Fecha de alta del registro:2024-11-23
Busca tu registro en:

Archivos desponibles
ArchivoDescripciónFormato
DocumentPrincipalDocumentPrincipalapplication/pdf

Información

© 2011 Universitat Rovira i Virgili