    Resum:
    A simple and highly sensitive approach was performed to synthesize a selective sulfaguanidine (SG) sensor based on a molecularly imprinted electropolymer of acrylamide (PAM) for honey quality control. SG was detected by measurements of electrochemical impedance spectroscopy (EIS) and differential pulse voltammetry (DPV). These techniques were applied successfully to determine SG with an excellent selectivity when compared to the results of interfering compounds. Furthermore, unprecedented, ultra-low limits of detection (LOD) and quantification (LOQ) of 0.20 pg·mL−1 and 0.67 pg·mL−1, respectively according to DPV measurements and 0.17 pg·mL−1 and 0.57 pg·mL−1 according to EIS measurements. The proposed approach is found to be inexpensive, selective and very sensitive, thanks to the good biocompatibility of SG/PAM composite. The results also showed that this sensor was successfully applied to detect SG residues in honey samples with recoveries between 83.9% and 99.7% and had the potential to be further developed for other multiple analytes detection, thus offering an emerging horizon for bio-sensing applications in honey quality control.
  • Altres:

    Autor segons l'article: El Alami El Hassani N., Llobet E., Popescu L., Ghita M., Bouchikhi B., El Bari N.
    Departament: Enginyeria Electrònica, Elèctrica i Automàtica
    Autor/s de la URV: Llobet Valero, Eduard
    Paraules clau: Sulfaguanidine Molecularly imprinted sensor Honey Food control Biomimetic
    Resum: A simple and highly sensitive approach was performed to synthesize a selective sulfaguanidine (SG) sensor based on a molecularly imprinted electropolymer of acrylamide (PAM) for honey quality control. SG was detected by measurements of electrochemical impedance spectroscopy (EIS) and differential pulse voltammetry (DPV). These techniques were applied successfully to determine SG with an excellent selectivity when compared to the results of interfering compounds. Furthermore, unprecedented, ultra-low limits of detection (LOD) and quantification (LOQ) of 0.20 pg·mL−1 and 0.67 pg·mL−1, respectively according to DPV measurements and 0.17 pg·mL−1 and 0.57 pg·mL−1 according to EIS measurements. The proposed approach is found to be inexpensive, selective and very sensitive, thanks to the good biocompatibility of SG/PAM composite. The results also showed that this sensor was successfully applied to detect SG residues in honey samples with recoveries between 83.9% and 99.7% and had the potential to be further developed for other multiple analytes detection, thus offering an emerging horizon for bio-sensing applications in honey quality control.
    Àrees temàtiques: Química Medicina ii Materiais Interdisciplinar General chemical engineering Farmacia Engenharias iv Engenharias iii Engenharias ii Electrochemistry Ciências biológicas ii Ciências biológicas i Ciências agrárias i Chemistry, analytical Chemical engineering (miscellaneous) Chemical engineering (all) Biotecnología Biodiversidade Astronomia / física Analytical chemistry
    Accès a la llicència d'ús: https://creativecommons.org/licenses/by/3.0/es/
    ISSN: 00220728
    Adreça de correu electrònic de l'autor: eduard.llobet@urv.cat
    Identificador de l'autor: 0000-0001-6164-4342
    Data d'alta del registre: 2024-09-07
    Versió de l'article dipositat: info:eu-repo/semantics/acceptedVersion
    Enllaç font original: https://www.sciencedirect.com/science/article/abs/pii/S1572665718304776
    URL Document de llicència: https://repositori.urv.cat/ca/proteccio-de-dades/
    Referència a l'article segons font original: Journal Of Electroanalytical Chemistry. 823 (823): 647-655
    Referència de l'ítem segons les normes APA: El Alami El Hassani N., Llobet E., Popescu L., Ghita M., Bouchikhi B., El Bari N. (2018). Development of a highly sensitive and selective molecularly imprinted electrochemical sensor for sulfaguanidine detection in honey samples. Journal Of Electroanalytical Chemistry, 823(823), 647-655. DOI: 10.1016/j.jelechem.2018.07.011
    DOI de l'article: 10.1016/j.jelechem.2018.07.011
    Entitat: Universitat Rovira i Virgili
    Any de publicació de la revista: 2018
    Tipus de publicació: Journal Publications
  • Paraules clau:

    Analytical Chemistry,Chemical Engineering (Miscellaneous),Chemistry, Analytical,Electrochemistry
    Sulfaguanidine
    Molecularly imprinted sensor
    Honey
    Food control
    Biomimetic
    Química
    Medicina ii
    Materiais
    Interdisciplinar
    General chemical engineering
    Farmacia
    Engenharias iv
    Engenharias iii
    Engenharias ii
    Electrochemistry
    Ciências biológicas ii
    Ciências biológicas i
    Ciências agrárias i
    Chemistry, analytical
    Chemical engineering (miscellaneous)
    Chemical engineering (all)
    Biotecnología
    Biodiversidade
    Astronomia / física
    Analytical chemistry
  • Documents:

  • Cerca a google

    Search to google scholar