Autor segons l'article: López J., Fortuny G., Puigjaner D., Herrero J., Marimon F.
Departament: Medicina i Cirurgia Enginyeria Informàtica i Matemàtiques Enginyeria Química
Autor/s de la URV: Fortuny Anguera, Gerard / Herrero Sabartés, Juan / López Besora, Josep Maria / Puigjaner Riba, Maria Dolores
Paraules clau: Wall shear stress Non-newtonian viscosity model Inferior vena cava filters Hemodynamics Drag coefficients Computational fluid dynamics non-newtonian viscosity model inferior vena cava filters hemodynamics drag coefficients computational fluid dynamics
Resum: Computational fluid dynamics was used to simulate the flow of blood within an inferior vena cava (IVC) geometry model that was reconstructed from computed tomography images obtained from a real patient. The main novelty of the present work is that we simulated the implantation of four different filter models in this real- istic IVC geometry. We considered different blood flow rates in the range between Vin= 20 and Vin= 80cm3∕s and all simulations were performed with both the Newtonian and a non-Newtonian model for the blood viscosity. We compared the hemodynamics performance of the different filter models and we paid a special atten- tion to the total drag force, Fd, exerted by the blood flow on the filter surface. This force is the sum of two contributions: the viscous skin friction force, which was found to be roughly proportional to the filter surface area, and the pressure force, which depended on the particular filter geometry design. The Fd force is relevant because it must be balanced by the total force exerted by the filter hooks/struts on the IVC wall at the attachment locations. For the highest Vin value investigated, the variation in Fd among filters was from 116 to 308 dyne. We also showed how the present results can be extrapolated to obtain good estimates of the drag forces if the blood viscosity levels change, i.e., if the patient with a filter implanted is treated with anticoagulant therapy.
Àrees temàtiques: Software Molecular biology Modeling and simulation Medicina ii Medicina i Mathematics, interdisciplinary applications Mathematical & computational biology Interdisciplinar Engineering, biomedical Engenharias iii Engenharias i Educação física Computational theory and mathematics Ciências biológicas ii Ciência da computação Biomedical engineering Applied mathematics
ISSN: 20407939
Adreça de correu electrònic de l'autor: gerard.fortuny@urv.cat dolors.puigjaner@urv.cat joan.herrero@urv.cat josep.m.lopez@urv.cat
Identificador de l'autor: 0000-0002-2500-7386 0000-0001-5251-2022 0000-0001-8501-1187 0000-0001-7541-8936
Data d'alta del registre: 2024-09-07
Volum de revista: 34
Versió de l'article dipositat: info:eu-repo/semantics/acceptedVersion
Enllaç font original: https://onlinelibrary.wiley.com/doi/abs/10.1002/cnm.2990
URL Document de llicència: https://repositori.urv.cat/ca/proteccio-de-dades/
Referència a l'article segons font original: International Journal For Numerical Methods In Biomedical Engineering. 34 (7): e2990-
Referència de l'ítem segons les normes APA: López J., Fortuny G., Puigjaner D., Herrero J., Marimon F. (2018). A comparative CFD study of four inferior vena cava filters. International Journal For Numerical Methods In Biomedical Engineering, 34(7), e2990-. DOI: 10.1002/cnm.2990
DOI de l'article: 10.1002/cnm.2990
Entitat: Universitat Rovira i Virgili
Any de publicació de la revista: 2018
Pàgina inicial: Article number e2990
Tipus de publicació: Journal Publications