Autor segons l'article: Saez, J; Hernandez, V; Goossens, J; De Kerf, G; Verellen, D
Departament: Ciències Mèdiques Bàsiques
Autor/s de la URV: Hernandez Masgrau, Victor
Paraules clau: Transmission Tps modelling Tps comissioning Radiotherapy planning, computer-assisted Radiotherapy dosage Radiotherapy Radiometry Radiation-field offset Photon Phantoms, imaging Particle accelerators Multileaf collimator Monte-carlo Models, biological Model Mlc modelling Imrt Humans Guideline
Resum: Modelling of the multi-leaf collimator (MLC) in treatment planning systems (TPS) is crucial for the dose calculation accuracy of intensity-modulated radiation therapy plans. However, no standardised methodology for their configuration exists to date. In this study we present a method that separates the effect of each dosimetric characteristic of the MLC, offering comprehensive equations for the determination of the configuration parameters used in the TPS model. The main advantage of the method is that it only requires prior knowledge of the nominal leaf width and is based on doses measured with a Farmer chamber, which is a very well established and robust methodology. Another significant advantage is the required time, since measuring the tests takes only about 30 minutes per energy. Firstly, we provide a theoretical general formalism in terms of the primary fluence constructed from the transmission map obtained from an MLC model for synchronous and asynchronous sweeping beams. Secondly, we apply the formalism to the RayStation TPS as a proof of concept and we derive analytical expressions that allow the determination of the configuration parameters (leaf tip width, tongue-and-groove width, x-position offset and MLC transmission) and describe how they intertwine. Finally, we apply the method to Varian's Millennium120 and HD120 MLCs in a TrueBeam linear accelerator for different energies and determine the optimal configuration parameters. The proposed procedure is much faster and streamlined than the typical trial-and-error methods and increases the accuracy of dose calculation in clinical plans. Additionally, the procedure can be useful for standardising the MLC configuration process and it exposes the limitations of the implemented MLC model, providing guidance for further improvement of these models in TPSs.
Àrees temàtiques: Saúde coletiva Radiology, nuclear medicine and imaging Radiology, nuclear medicine & medical imaging Radiological and ultrasound technology Psicología Odontología Medicina ii Medicina i Matemática / probabilidade e estatística Interdisciplinar General medicine Engineering, biomedical Engenharias iv Engenharias iii Engenharias ii Ciências biológicas ii Ciências biológicas i Ciência da computação Astronomia / física
Accès a la llicència d'ús: https://creativecommons.org/licenses/by/3.0/es/
Adreça de correu electrònic de l'autor: victor.hernandez@urv.cat
Identificador de l'autor: 0000-0003-3770-8486
Data d'alta del registre: 2024-06-28
Versió de l'article dipositat: info:eu-repo/semantics/publishedVersion
Enllaç font original: https://iopscience.iop.org/article/10.1088/1361-6560/ab8cd5
Referència a l'article segons font original: Physics In Medicine And Biology. 65 (15): 155006-
Referència de l'ítem segons les normes APA: Saez, J; Hernandez, V; Goossens, J; De Kerf, G; Verellen, D (2020). A novel procedure for determining the optimal: MLC. configuration parameters in treatment planning systems based on measurements with a Farmer chamber. Physics In Medicine And Biology, 65(15), 155006-. DOI: 10.1088/1361-6560/ab8cd5