Analysis of electrode performance on amplitude integrated electroencephalography in neonates: evaluation of a new electrode aCUP-E vs. liquid gel electrodes

  • Dades identificatives

    Identificador: imarina:9387469
    Autors:
    Fabregat-Sanjuan, AlbertRodriguez-Ballabriga, AngelRigo-Vidal, AgnesPamies-Vila, RosaLarrosa-Capaces, SusanaRius-Costa, VanesaPascual-Rubio, Vicenc
    Resum:
    Background Neonatologists and clinical neurophysiologists face challenges with the current electrodes used for long-duration amplitude-integrated electroencephalography (aEEG) in neonatal intensive care units (NICU), limiting the capacity to diagnose brain damage.Objectives The objectives of this study were to develop methods for comparing the performance of different electrodes to be used in aEEG. The comparison was done between a newly designed neonate-specific electrode, aCUP-E, with commercial liquid gel electrodes used in amplitude-integrated electroencephalography (aEEG). The comparison included impedance stability, electrode survival, recording quality, usability, and satisfaction of NICU staff.Methods aEEG recordings with bipolar montage was used, with one hemisphere fitted with commercial electrodes and the other with aCUP-E electrodes, alternated among subjects. Continuous impedance and raw EEG data were collected over a minimum of 24 h, and signal processing was performed using Python and MATLAB.Main results aCUP-E electrodes demonstrated superior performance, including: Increased impedance stability and electrode survival, enhanced recording quality with fewer artifacts, high correlation in signal capture between electrodes during optimal brain activity segments, higher signal-to-noise ratio (SNR) across varying impedance levels, greater staff satisfaction and ease of use. Moreover, Kaplan-Meier curves indicated a higher survival rate for aCUP-E electrodes over 24 h compared to commercial electrodes. Impedance variability analysis showed statistically significant stability improvements for aCUP-E.Conclusion aCUP-E electrodes outperform commercial liquid gel electrodes in impedance stability, electrode survival, and recording quality. These results suggest th
  • Altres:

    Autor segons l'article: Fabregat-Sanjuan, Albert; Rodriguez-Ballabriga, Angel; Rigo-Vidal, Agnes; Pamies-Vila, Rosa; Larrosa-Capaces, Susana; Rius-Costa, Vanesa; Pascual-Rubio, Vicenc
    Departament: Enginyeria Mecànica
    Autor/s de la URV: Fabregat Sanjuan, Albert
    Paraules clau: Acup-e Aeeg Challenge Electrodes Impedance Neonatal intensive care unit Neonates Preterm Preterm infants Signal artifact Signal artifacts
    Resum: Background Neonatologists and clinical neurophysiologists face challenges with the current electrodes used for long-duration amplitude-integrated electroencephalography (aEEG) in neonatal intensive care units (NICU), limiting the capacity to diagnose brain damage.Objectives The objectives of this study were to develop methods for comparing the performance of different electrodes to be used in aEEG. The comparison was done between a newly designed neonate-specific electrode, aCUP-E, with commercial liquid gel electrodes used in amplitude-integrated electroencephalography (aEEG). The comparison included impedance stability, electrode survival, recording quality, usability, and satisfaction of NICU staff.Methods aEEG recordings with bipolar montage was used, with one hemisphere fitted with commercial electrodes and the other with aCUP-E electrodes, alternated among subjects. Continuous impedance and raw EEG data were collected over a minimum of 24 h, and signal processing was performed using Python and MATLAB.Main results aCUP-E electrodes demonstrated superior performance, including: Increased impedance stability and electrode survival, enhanced recording quality with fewer artifacts, high correlation in signal capture between electrodes during optimal brain activity segments, higher signal-to-noise ratio (SNR) across varying impedance levels, greater staff satisfaction and ease of use. Moreover, Kaplan-Meier curves indicated a higher survival rate for aCUP-E electrodes over 24 h compared to commercial electrodes. Impedance variability analysis showed statistically significant stability improvements for aCUP-E.Conclusion aCUP-E electrodes outperform commercial liquid gel electrodes in impedance stability, electrode survival, and recording quality. These results suggest that aCUP-E electrodes could significantly enhance aEEG utilization in diagnosing and treating neonatal brain conditions in NICUs. Future improvements to the aCUP-E electrode may further reduce artifacts and increase electrode longevity, potentially leading to a significant improvement in neonatal brain monitoring by means of aEEG.
    Àrees temàtiques: Ciências biológicas i Farmacia Medicina i Medicina ii Medicina iii Pediatrics Pediatrics, perinatology and child health
    Accès a la llicència d'ús: https://creativecommons.org/licenses/by/3.0/es/
    Adreça de correu electrònic de l'autor: a.fabregat@urv.cat
    Identificador de l'autor: 0000-0002-2878-1369
    Data d'alta del registre: 2024-11-09
    Versió de l'article dipositat: info:eu-repo/semantics/publishedVersion
    Referència a l'article segons font original: Frontiers In Pediatrics. 12 1452862-
    Referència de l'ítem segons les normes APA: Fabregat-Sanjuan, Albert; Rodriguez-Ballabriga, Angel; Rigo-Vidal, Agnes; Pamies-Vila, Rosa; Larrosa-Capaces, Susana; Rius-Costa, Vanesa; Pascual-Rubi (2024). Analysis of electrode performance on amplitude integrated electroencephalography in neonates: evaluation of a new electrode aCUP-E vs. liquid gel electrodes. Frontiers In Pediatrics, 12(), 1452862-. DOI: 10.3389/fped.2024.1452862
    URL Document de llicència: https://repositori.urv.cat/ca/proteccio-de-dades/
    Entitat: Universitat Rovira i Virgili
    Any de publicació de la revista: 2024
    Tipus de publicació: Journal Publications
  • Paraules clau:

    Pediatrics,Pediatrics, Perinatology and Child Health
    Acup-e
    Aeeg
    Challenge
    Electrodes
    Impedance
    Neonatal intensive care unit
    Neonates
    Preterm
    Preterm infants
    Signal artifact
    Signal artifacts
    Ciências biológicas i
    Farmacia
    Medicina i
    Medicina ii
    Medicina iii
    Pediatrics
    Pediatrics, perinatology and child health
  • Documents:

  • Cerca a google

    Search to google scholar