Articles producció científica> Medicina i Cirurgia

A comparative CFD study of four inferior vena cava filters

  • Datos identificativos

    Identificador: imarina:5131987
    Autores:
    López J., Fortuny G., Puigjaner D., Herrero J., Marimon F.
    Resumen:
    Computational fluid dynamics was used to simulate the flow of blood within an inferior vena cava (IVC) geometry model that was reconstructed from computed tomography images obtained from a real patient. The main novelty of the present work is that we simulated the implantation of four different filter models in this real- istic IVC geometry. We considered different blood flow rates in the range between Vin= 20 and Vin= 80cm3∕s and all simulations were performed with both the Newtonian and a non-Newtonian model for the blood viscosity. We compared the hemodynamics performance of the different filter models and we paid a special atten- tion to the total drag force, Fd, exerted by the blood flow on the filter surface. This force is the sum of two contributions: the viscous skin friction force, which was found to be roughly proportional to the filter surface area, and the pressure force, which depended on the particular filter geometry design. The Fd force is relevant because it must be balanced by the total force exerted by the filter hooks/struts on the IVC wall at the attachment locations. For the highest Vin value investigated, the variation in Fd among filters was from 116 to 308 dyne. We also showed how the present results can be extrapolated to obtain good estimates of the drag forces if the blood viscosity levels change, i.e., if the patient with a filter implanted is treated with anticoagulant therapy.
  • Otros:

    Autor según el artículo: López J., Fortuny G., Puigjaner D., Herrero J., Marimon F.
    Departamento: Medicina i Cirurgia Enginyeria Informàtica i Matemàtiques Enginyeria Química
    Autor/es de la URV: Fortuny Anguera, Gerard / Herrero Sabartés, Juan / López Besora, Josep Maria / Puigjaner Riba, Maria Dolores
    Palabras clave: Wall shear stress Non-newtonian viscosity model Inferior vena cava filters Hemodynamics Drag coefficients Computational fluid dynamics non-newtonian viscosity model inferior vena cava filters hemodynamics drag coefficients computational fluid dynamics
    Resumen: Computational fluid dynamics was used to simulate the flow of blood within an inferior vena cava (IVC) geometry model that was reconstructed from computed tomography images obtained from a real patient. The main novelty of the present work is that we simulated the implantation of four different filter models in this real- istic IVC geometry. We considered different blood flow rates in the range between Vin= 20 and Vin= 80cm3∕s and all simulations were performed with both the Newtonian and a non-Newtonian model for the blood viscosity. We compared the hemodynamics performance of the different filter models and we paid a special atten- tion to the total drag force, Fd, exerted by the blood flow on the filter surface. This force is the sum of two contributions: the viscous skin friction force, which was found to be roughly proportional to the filter surface area, and the pressure force, which depended on the particular filter geometry design. The Fd force is relevant because it must be balanced by the total force exerted by the filter hooks/struts on the IVC wall at the attachment locations. For the highest Vin value investigated, the variation in Fd among filters was from 116 to 308 dyne. We also showed how the present results can be extrapolated to obtain good estimates of the drag forces if the blood viscosity levels change, i.e., if the patient with a filter implanted is treated with anticoagulant therapy.
    Áreas temáticas: Software Molecular biology Modeling and simulation Medicina ii Medicina i Mathematics, interdisciplinary applications Mathematical & computational biology Interdisciplinar Engineering, biomedical Engenharias iii Engenharias i Educação física Computational theory and mathematics Ciências biológicas ii Ciência da computação Biomedical engineering Applied mathematics
    ISSN: 20407939
    Direcció de correo del autor: gerard.fortuny@urv.cat dolors.puigjaner@urv.cat joan.herrero@urv.cat josep.m.lopez@urv.cat
    Identificador del autor: 0000-0002-2500-7386 0000-0001-5251-2022 0000-0001-8501-1187 0000-0001-7541-8936
    Fecha de alta del registro: 2024-09-07
    Volumen de revista: 34
    Versión del articulo depositado: info:eu-repo/semantics/acceptedVersion
    URL Documento de licencia: https://repositori.urv.cat/ca/proteccio-de-dades/
    Referencia al articulo segun fuente origial: International Journal For Numerical Methods In Biomedical Engineering. 34 (7): e2990-
    Referencia de l'ítem segons les normes APA: López J., Fortuny G., Puigjaner D., Herrero J., Marimon F. (2018). A comparative CFD study of four inferior vena cava filters. International Journal For Numerical Methods In Biomedical Engineering, 34(7), e2990-. DOI: 10.1002/cnm.2990
    Entidad: Universitat Rovira i Virgili
    Año de publicación de la revista: 2018
    Página inicial: Article number e2990
    Tipo de publicación: Journal Publications
  • Palabras clave:

    Applied Mathematics,Biomedical Engineering,Computational Theory and Mathematics,Engineering, Biomedical,Mathematical & Computational Biology,Mathematics, Interdisciplinary Applications,Modeling and Simulation,Molecular Biology,Software
    Wall shear stress
    Non-newtonian viscosity model
    Inferior vena cava filters
    Hemodynamics
    Drag coefficients
    Computational fluid dynamics
    non-newtonian viscosity model
    inferior vena cava filters
    hemodynamics
    drag coefficients
    computational fluid dynamics
    Software
    Molecular biology
    Modeling and simulation
    Medicina ii
    Medicina i
    Mathematics, interdisciplinary applications
    Mathematical & computational biology
    Interdisciplinar
    Engineering, biomedical
    Engenharias iii
    Engenharias i
    Educação física
    Computational theory and mathematics
    Ciências biológicas ii
    Ciência da computação
    Biomedical engineering
    Applied mathematics
  • Documentos:

  • Cerca a google

    Search to google scholar