Autor/s de la URV: | Prieto Simón, Beatriz |
Autor segons l'article: | Shiohara A; Easton CD; Prieto-Simon B; Voelcker NH |
Adreça de correu electrònic de l'autor: | beatriz.prieto-simon@urv.cat |
Identificador de l'autor: | 0000-0001-8016-1565 |
Any de publicació de la revista: | 2022 |
Tipus de publicació: | Journal Publications |
Referència de l'ítem segons les normes APA: | Shiohara A; Easton CD; Prieto-Simon B; Voelcker NH (2022). Electrochemical Biosensors Based on Convectively Assembled Colloidal Crystals. Biosensors, 12(7), -. DOI: 10.3390/bios12070480 |
Referència a l'article segons font original: | Biosensors. 12 (7): |
Resum: | Rapid, sensitive, selective and portable virus detection is in high demand globally. How-ever, differentiating non-infectious viral particles from intact/infectious viruses is still a rarely satisfied sensing requirement. Using the negative space within monolayers of polystyrene (PS) spheres deposited directly on gold electrodes, we fabricated tuneable nanochannels decorated with target-selective bioreceptors that facilitate the size-selective detection of intact viruses. Detection occurred through selective nanochannel blockage of diffusion of a redox probe, [Fe(CN)6]3/4−, allowing a quantifiable change in the oxidation current before and after analyte binding to the bioreceptor immobilised on the spheres. Our model system involved partial surface passivation of the mono-assembled PS spheres, by silica glancing angle deposition, to confine bioreceptor immobilisation specifically to the channels and improve particle detection sensitivity. Virus detection was first optimised and modelled with biotinylated gold nanoparticles, recognised by streptavidin immobilised on the PS layer, reaching a low limit of detection of 37 particles/mL. Intact, label-free virus detection was demonstrated using MS2 bacteriophage (~23–28 nm), a marker of microbiological contamination, showing an excellent limit of detection of ~1.0 pfu/mL. Tuneable nanochannel geometries constructed directly on sensing electrodes offer label-free, sensitive, and cost-efficient point-of-care biosensing platforms that could be applied for a wide range of viruses. |
DOI de l'article: | 10.3390/bios12070480 |
Enllaç font original: | https://www.mdpi.com/2079-6374/12/7/480 |
Versió de l'article dipositat: | info:eu-repo/semantics/publishedVersion |
Accès a la llicència d'ús: | https://creativecommons.org/licenses/by/3.0/es/ |
Departament: | Enginyeria Electrònica, Elèctrica i Automàtica |
URL Document de llicència: | https://repositori.urv.cat/ca/proteccio-de-dades/ |
Àrees temàtiques: | Química Nanoscience & nanotechnology Medicine (miscellaneous) Materiais Instruments & instrumentation Instrumentation Engineering (miscellaneous) Clinical biochemistry Ciencias sociales Ciências biológicas iii Ciências biológicas i Chemistry, analytical Biotecnología Biotechnology Biomedical engineering Astronomia / física Analytical chemistry |
Paraules clau: | Virus detection Surface modification Electrochemical biosensors Convective assembly Colloidal crystal water virus detection pathogens nanoparticles convective assembly colloidal crystal beads bacteriophage-ms2 |
Entitat: | Universitat Rovira i Virgili |
Data d'alta del registre: | 2024-08-31 |
Descripció: | Rapid, sensitive, selective and portable virus detection is in high demand globally. How-ever, differentiating non-infectious viral particles from intact/infectious viruses is still a rarely satisfied sensing requirement. Using the negative space within monolayers of polystyrene (PS) spheres deposited directly on gold electrodes, we fabricated tuneable nanochannels decorated with target-selective bioreceptors that facilitate the size-selective detection of intact viruses. Detection occurred through selective nanochannel blockage of diffusion of a redox probe, [Fe(CN)6]3/4−, allowing a quantifiable change in the oxidation current before and after analyte binding to the bioreceptor immobilised on the spheres. Our model system involved partial surface passivation of the mono-assembled PS spheres, by silica glancing angle deposition, to confine bioreceptor immobilisation specifically to the channels and improve particle detection sensitivity. Virus detection was first optimised and modelled with biotinylated gold nanoparticles, recognised by streptavidin immobilised on the PS layer, reaching a low limit of detection of 37 particles/mL. Intact, label-free virus detection was demonstrated using MS2 bacteriophage (~23–28 nm), a marker of microbiological contamination, showing an excellent limit of detection of ~1.0 pfu/mL. Tuneable nanochannel geometries constructed directly on sensing electrodes offer label-free, sensitive, and cost-efficient point-of-care biosensing platforms that could be applied for a wide range of viruses. |
Tipus: | Journal Publications |
Coautor: | Universitat Rovira i Virgili |
Títol: | Electrochemical Biosensors Based on Convectively Assembled Colloidal Crystals |
Matèria: | Analytical Chemistry,Biomedical Engineering,Biotechnology,Chemistry, Analytical,Clinical Biochemistry,Instrumentation,Instruments & Instrumentation,Medicine (Miscellaneous),Nanoscience & Nanotechnology Virus detection Surface modification Electrochemical biosensors Convective assembly Colloidal crystal water virus detection pathogens nanoparticles convective assembly colloidal crystal beads bacteriophage-ms2 Química Nanoscience & nanotechnology Medicine (miscellaneous) Materiais Instruments & instrumentation Instrumentation Engineering (miscellaneous) Clinical biochemistry Ciencias sociales Ciências biológicas iii Ciências biológicas i Chemistry, analytical Biotecnología Biotechnology Biomedical engineering Astronomia / física Analytical chemistry |
Data: | 2022 |
Autor: | Shiohara A Easton CD Prieto-Simon B Voelcker NH |
Drets: | info:eu-repo/semantics/openAccess |
Cerca el teu registre a: |
Fitxer | Descripció | Format | |
---|---|---|---|
DocumentPrincipal | DocumentPrincipal | application/pdf |
© 2011 Universitat Rovira i Virgili