Repositori institucional URV
Pertany a la col·lecció PC:SerieArticles
TÍTOL:
Graphene-based potentiometric biosensor for the immediate detection of living bacteria - imarina:9378686
Handle:
https://hdl.handle.net/20.500.11797/imarina9378686
Autor/s de la URV:
HERNÁNDEZ OTER, RAMÓN / Riu Rusell, Jordi / Rius Ferrús, Francisco Javier / RIUS RUIZ, FRANCESC XAVIER
Autor segons l'article:
Hernández R; Vallés C; Benito AM; Maser WK; Xavier Rius F; Riu J
Adreça de correu electrònic de l'autor:
jordi.riu@urv.cat
Identificador de l'autor
:
0000-0001-5823-9223
Any de publicació de la revista:
2014
Tipus de publicació:
Journal Publications
Referència de l'ítem segons les normes APA
:
Hernández R; Vallés C; Benito AM; Maser WK; Xavier Rius F; Riu J (2014). Graphene-based potentiometric biosensor for the immediate detection of living bacteria. Biosensors & Bioelectronics, 54(), 553-557. DOI: 10.1016/j.bios.2013.11.053
Referència a l'article segons font original
:
Biosensors & Bioelectronics. 54 553-557
Resum:
In this communication we present a potentiometric aptasensor based on chemically modified graphene (transducer layer of the aptasensor) and aptamers (sensing layer). Graphene oxide (GO) and reduced graphene oxide (RGO) are the basis for the construction of two versions of the aptasensor for the detection of a challenging living organism such as Staphylococcus aureus. In these two versions, DNA aptamers are either covalently (in the GO case) or non-covalently (in the RGO case) attached to the transducer layer. In both cases we are able to selectively detect a single CFU/mL of S. aureus in an assay close to real time, although the noise level associated to the aptasensors made with RGO is lower than the ones made with GO. These new aptasensors, that show a high selectivity, are characterized by the simplicity of the technique and the materials used for their construction while offering ultra-low detection limits in very short time responses in the detection of microorganisms. © 2013 Elsevier B.V.
DOI de l'article:
10.1016/j.bios.2013.11.053
Enllaç font original:
https://www.sciencedirect.com/science/article/abs/pii/S0956566313008439
Versió de l'article dipositat:
info:eu-repo/semantics/acceptedVersion
Accès a la llicència d'ús:
https://creativecommons.org/licenses/by/3.0/es/
Departament:
Química Analítica i Química Orgànica
URL Document de llicència:
https://repositori.urv.cat/ca/proteccio-de-dades/
Àrees temàtiques:
Química
Nanoscience and nanotechnology
Nanoscience & nanotechnology
Medicine (miscellaneous)
Medicina ii
Medicina i
Materiais
Interdisciplinar
Farmacia
Engenharias iv
Engenharias iii
Engenharias ii
Electrochemistry
Economia
Ciências biológicas iii
Ciências biológicas ii
Ciências biológicas i
Ciências ambientais
Ciências agrárias i
Chemistry, analytical
Biotecnología
Biotechnology & applied microbiology
Biotechnology
Biophysics
Biomedical engineering
Biodiversidade
Astronomia / física
Paraules clau:
Graphene
Biosensor
Bacteria
Aptamer
biosensor
bacteria
aptamer
Entitat:
Universitat Rovira i Virgili
Data d'alta del registre:
2024-10-12
Descripció:
In this communication we present a potentiometric aptasensor based on chemically modified graphene (transducer layer of the aptasensor) and aptamers (sensing layer). Graphene oxide (GO) and reduced graphene oxide (RGO) are the basis for the construction of two versions of the aptasensor for the detection of a challenging living organism such as Staphylococcus aureus. In these two versions, DNA aptamers are either covalently (in the GO case) or non-covalently (in the RGO case) attached to the transducer layer. In both cases we are able to selectively detect a single CFU/mL of S. aureus in an assay close to real time, although the noise level associated to the aptasensors made with RGO is lower than the ones made with GO. These new aptasensors, that show a high selectivity, are characterized by the simplicity of the technique and the materials used for their construction while offering ultra-low detection limits in very short time responses in the detection of microorganisms. © 2013 Elsevier B.V.
Tipus:
Journal Publications
info:eu-repo/semantics/acceptedVersion
Coautor:
Química Analítica i Química Orgànica
Universitat Rovira i Virgili
Títol:
Graphene-based potentiometric biosensor for the immediate detection of living bacteria
Matèria:
Biomedical Engineering,Biophysics,Biotechnology,Biotechnology & Applied Microbiology,Chemistry, Analytical,Electrochemistry,Medicine (Miscellaneous),Nanoscience & Nanotechnology,Nanoscience and Nanotechnology
Graphene
Biosensor
Bacteria
Aptamer
biosensor
bacteria
aptamer
Química
Nanoscience and nanotechnology
Nanoscience & nanotechnology
Medicine (miscellaneous)
Medicina ii
Medicina i
Materiais
Interdisciplinar
Farmacia
Engenharias iv
Engenharias iii
Engenharias ii
Electrochemistry
Economia
Ciências biológicas iii
Ciências biológicas ii
Ciências biológicas i
Ciências ambientais
Ciências agrárias i
Chemistry, analytical
Biotecnología
Biotechnology & applied microbiology
Biotechnology
Biophysics
Biomedical engineering
Biodiversidade
Astronomia / física
Data:
2014
Autor:
Hernández R
Vallés C
Benito AM
Maser WK
Xavier Rius F
Riu J
Drets:
info:eu-repo/semantics/openAccess
Cerca el teu registre a:
Fitxers disponibles
Fitxer
Descripció
Format
DocumentPrincipal
DocumentPrincipal
application/pdf
Veure/Obrir
Veure registre complet
Tornar
Tots els objectes d'aquesta col·lecció
Informació
© 2011 Universitat Rovira i Virgili
Nota legal
Accessibilitat
Contacte