Autor segons l'article: Margalef, Ramón; Minaya-Muñoz, Francisco; Valera-Garrido, Fermín; Bosque, Marc; Santafé, Manel M.
Departament: Psicologia Ciències Mèdiques Bàsiques
Autor/s de la URV: Bosque Alberich, Marc / MARGALEF CATALÀ, RAMON / Santafé Martínez, Manuel
Paraules clau: Clean water and sanitation
Resum: <jats:title>Abstract</jats:title><jats:p>
Aim?To determine whether sodium chloride electrolysis causes a change in the pH of tissues.</jats:p><jats:p>
Methods?The effects of a 3?mA galvanic current has been evaluated, applied for 3?seconds and 3 repetitions (3:3:3). In vitro pH changes were evaluated in three experiments: 1) Eppendorf® tubes filled with Ringer's solution; 2) a very small volume of Ringer's solution (100µl); 3) Eppendorf® tubes filled with saline solution (NaCl 0.9%). The pH changes in the gastrocnemius of mice were evaluated, using the left limb as a control and the right limb for the intervention. The gastrocnemius muscles were ground up and the pH of each group was determined.</jats:p><jats:p>
Results?In the in vitro experiments 1 and 2, no variation was observed in the pH of either the cathode in the Ringer's solution or the anode in the Ringer's solution (the variation did not exceed 16% in either of the cases, p> 0.05). In the third in vitro study, the pH after galvanic current application increased by 70% in the saline solution of the cathode and the anode pH decreased by 34% (p?<?0.05 in both cases). In the in vivo experiments, no change in pH was obtained (% variation: 0.00?±?0.00).</jats:p><jats:p>
Conclusions?The galvanic current used in percutaneous needle electrolysis applying the 3:3:3 parameters generates very small changes in the pH, in the area near the needle, which the body is able to rapidly compensate for.</jats:p>
Accès a la llicència d'ús: https://creativecommons.org/licenses/by/3.0/es/
Adreça de correu electrònic de l'autor: manuel.santafe@urv.cat
Identificador de l'autor: 0000-0002-5462-5108
Data d'alta del registre: 2024-11-23
Versió de l'article dipositat: info:eu-repo/semantics/publishedVersion
URL Document de llicència: https://repositori.urv.cat/ca/proteccio-de-dades/
Referència a l'article segons font original: Revista Fisioterapia Invasiva / Journal Of Invasive Techniques In Physical Therapy. 03 (01): 006-006
Referència de l'ítem segons les normes APA: Margalef, Ramón; Minaya-Muñoz, Francisco; Valera-Garrido, Fermín; Bosque, Marc; Santafé, Manel M. (2020). Changes in pH as a result of galvanic currents used in percutaneous needle electrolysis. Revista Fisioterapia Invasiva / Journal Of Invasive Techniques In Physical Therapy, 03(01), 006-006. DOI: 10.1055/s-0040-1712511
Entitat: Universitat Rovira i Virgili
Any de publicació de la revista: 2020
Tipus de publicació: Journal Publications