Articles producció científica> Enginyeria Mecànica

Experimental investigation on the flow behaviour in a bubble pump of diffusion absorption refrigeration systems

  • Identification data

    Identifier: PC:1496
  • Authors:

    Mahmoud Bourouis
    Ali Benhmidene
    KhaoulaHidouri
    BéchirChaouachi
    SlimaneGabsi
  • Others:

    Author, as appears in the article.: Mahmoud Bourouis; Ali Benhmidene; KhaoulaHidouri; BéchirChaouachi; SlimaneGabsi
    Department: Enginyeria Mecànica
    URV's Author/s: BOUROUIS CHEBATA, MAHMOUD; Ali Benhmidene; KhaoulaHidouri; BéchirChaouachi; SlimaneGabsi
    Keywords: Flow pattern Diffusion absorption refrigeration Bubble pump
    Abstract: An experimental investigation on the performance of a bubble pump for diffusion absorption refrigeration (DAR) systems was carried-out. The characteristics and operating conditions of the bubble pump determine the efficiency of the DAR systems. An experimental set-up operating in continuous mode was designed, built-up and successfully operated as a bubble pump. Experiments were performed by changing some of the parameters affecting the bubble pump performance. The experimental results showed that the performance of the bubble pump was mainly dependent on the driving heat input and the submersion ratio. Driving heat inputs applied were between 20 W and 200 W for a suitable size of the pump tubes. Three submersion ratios were tested, namely 25%, 35% and 45%. The results obtained showed that an oscillating flow was present in the operation of the bubble pump and the frequency of oscillation increased with the increase of the submersion ratio. The average mass flow rate of the refrigerant (ammonia) pumped increased with increase in the heating power; however, mass flow rates of the poor and rich solutions were function of the flow regime. In addition, experimental results were used to determine the optimal heating power for the different submersion ratios considered in this study. The optimal heating power ranged from 30 W to 130 W for a submersion ratio of 25% and from 30 W to 80 W for the submersion ratios of 35% and 45%.
    Research group: CREVER-Grup Enginyeria Tèrmica Aplicada
    Thematic Areas: Mechanical engineering Ingeniería mecánica Enginyeria mecànica
    licence for use: https://creativecommons.org/licenses/by/3.0/es/
    ISSN: 2214-157X
    Author identifier: 0000-0003-2476-5967; n/a; n/a; n/a; n/a
    Record's date: 2016-05-18
    Last page: 9
    Journal volume: 8
    Papper version: info:eu-repo/semantics/publishedVersion
    Link to the original source: https://www.sciencedirect.com/science/article/pii/S2214157X16300156?via%3Dihub
    Licence document URL: https://repositori.urv.cat/ca/proteccio-de-dades/
    Article's DOI: 10.1016/j.csite.2016.04.002
    Entity: Universitat Rovira i Virgili
    Journal publication year: 2016
    First page: 1
    Publication Type: Article Artículo Article
  • Keywords:

    Refrigeració
    Calor -- Radiació i absorció
    Flow pattern
    Diffusion absorption refrigeration
    Bubble pump
    Mechanical engineering
    Ingeniería mecánica
    Enginyeria mecànica
    2214-157X
  • Documents:

  • Cerca a google

    Search to google scholar