Articles producció científica> Química Analítica i Química Orgànica

Comparative study of different fabric sorptive extraction sorbents to determine emerging contaminants from environmental water using liquid-chromatography-tandem mass spectrometry 

  • Identification data

    Identifier: PC:3022
    Authors:
    Borrull, F.Lakade, S.Furton, K.Kabir, A.Fontanals, N.Marcé, R. M.
    Abstract:
    A new sorptive extraction technique, fabric phase sorptive extraction (FPSE), using different coating chemistries: non-polar sol-gel poly(dimethyldiphenylsiloxane) (PDMDPS), medium polar sol-gel poly(tetrahydrofuran) (PTHF), and polar sol-gel poly(ethylene glycol)-block-poly(propylene glycol)-block-poly(ethylene glycol) (PEG-PPG-PEG triblock) and sol-gel Carbowax 20M were evaluated to extract a group of pharmaceuticals and personal care products (PPCPs) with wide range of polarity from environmental aqueous samples. Different parameters affecting FPSE such as sample pH, stirring speed, addition of salt, extraction time, sample volume, elution solvent and desorption time were optimized for each sorbent coated FPSE media. Under optimum conditions, FPSE media coated with sol-gel Carbowax 20M provided the highest absolute recoveries (77-85%) for majority of the analytes with the exception of the most polar ones. Nevertheless, all four sorbents offered better recovery compared to the commercially available coating for stir-bar sorptive extraction based on Ethylene Glycol/Silicone (EG/Silicone). The method based on FPSE with sol-gel Carbowax 20M media and liquid chromatography–(electrospray ionization) tandem mass spectrometry (LC-(ESI) MS/MS) was developed and validated for environmental water samples. Good apparent recoveries (41 - 80%), detection limits (1 - 50 ng L-1), repeatability (%RSD<15%, n=5) and reproducibility (%RSD<18%, n=5) were achieved.
  • Others:

    Author, as appears in the article.: Borrull, F. ; Lakade, S. ; Furton, K.; Kabir, A. ; Fontanals, N. ; Marcé, R. M.
    Department: Química Analítica i Química Orgànica
    URV's Author/s: BORRULL BALLARÍN, FRANCESC; Lakade, S. ; Furton, K.; Kabir, A. ; Fontanals, N. ; MARCÉ RECASENS, ROSA MARIA
    Keywords: Fabric phase sorptive extraction Carbowax 20M sorbent Liquid chromatography¿tandem mass spectrometry
    Abstract: A new sorptive extraction technique, fabric phase sorptive extraction (FPSE), using different coating chemistries: non-polar sol-gel poly(dimethyldiphenylsiloxane) (PDMDPS), medium polar sol-gel poly(tetrahydrofuran) (PTHF), and polar sol-gel poly(ethylene glycol)-block-poly(propylene glycol)-block-poly(ethylene glycol) (PEG-PPG-PEG triblock) and sol-gel Carbowax 20M were evaluated to extract a group of pharmaceuticals and personal care products (PPCPs) with wide range of polarity from environmental aqueous samples. Different parameters affecting FPSE such as sample pH, stirring speed, addition of salt, extraction time, sample volume, elution solvent and desorption time were optimized for each sorbent coated FPSE media. Under optimum conditions, FPSE media coated with sol-gel Carbowax 20M provided the highest absolute recoveries (77-85%) for majority of the analytes with the exception of the most polar ones. Nevertheless, all four sorbents offered better recovery compared to the commercially available coating for stir-bar sorptive extraction based on Ethylene Glycol/Silicone (EG/Silicone). The method based on FPSE with sol-gel Carbowax 20M media and liquid chromatography–(electrospray ionization) tandem mass spectrometry (LC-(ESI) MS/MS) was developed and validated for environmental water samples. Good apparent recoveries (41 - 80%), detection limits (1 - 50 ng L-1), repeatability (%RSD<15%, n=5) and reproducibility (%RSD<18%, n=5) were achieved.
    Research group: Grup de Cromatografia. Aplicacions Mediambientals
    Thematic Areas: Química Química Chemistry
    licence for use: https://creativecommons.org/licenses/by/3.0/es/
    ISSN: 0039-9140
    Author identifier: 0000-0003-2718-9336; ; ; ; ; 0000-0002-5667-2899
    Record's date: 2018-02-28
    Last page: 1351
    Journal volume: 144
    Papper version: info:eu-repo/semantics/acceptedVersion
    Link to the original source: https://www.sciencedirect.com/science/article/abs/pii/S0039914015302290
    Funding program: plan; CTQ2011-24179 plan; Excelencia; CTQ2014- 52617-P
    Licence document URL: https://repositori.urv.cat/ca/proteccio-de-dades/
    Article's DOI: 10.1016/j.talanta.2015.08.009
    Entity: Universitat Rovira i Virgili
    Journal publication year: 2015
    First page: 1342
    Publication Type: Article Artículo Article
  • Keywords:

    Extracció (Química)
    Cromatografia de líquids
    Espectrometria de masses
    Fabric phase sorptive extraction
    Carbowax 20M sorbent
    Liquid chromatography¿tandem mass spectrometry
    Química
    Química
    Chemistry
    0039-9140