Articles producció científicaEnginyeria Electrònica, Elèctrica i Automàtica

Use of a CNT-coated piezoelectric cantilever with double transduction as a gas sensor for benzene detection at room temperature

  • Identification data

    Identifier:  imarina:5609693
    Authors:  Clement, P; Llobet, E; Lucat, C; Debeda, H
    Abstract:
    © 2014 The Authors. Published by Elsevier Ltd. In this work, we propose to use a screen-printed piezoelectric cantilever with double transduction. Indeed, the piezoelectric cantilever is used as a resonant type sensor coated with carbon nanotubes (CNTs) as sensitive layer. Then, the resistance of CNTs is measured in static mode in parallel thanks to a modification of the cantilever top electrode. The combination of the CNTs equilibrium conductivity measurement and the resonance frequency shift of the 31-longitudinal mode allows the use of this device as a chemical gas sensor for benzene detection. The responses towards benzene concentrations under different relative humidity backgrounds are discussed.
  • Others:

    Link to the original source: https://www.sciencedirect.com/science/article/pii/S1877705814027519
    APA: Clement, P; Llobet, E; Lucat, C; Debeda, H (2014). Use of a CNT-coated piezoelectric cantilever with double transduction as a gas sensor for benzene detection at room temperature. Amsterdam: Elsevier
    Paper original source: Procedia Engineering. 87 708-711
    Article's DOI: 10.1016/j.proeng.2014.11.636
    Journal publication year: 2014
    Entity: Universitat Rovira i Virgili
    Paper version: info:eu-repo/semantics/publishedVersion
    Record's date: 2024-10-12
    URV's Author/s: Llobet Valero, Eduard
    Department: Enginyeria Electrònica, Elèctrica i Automàtica
    Licence document URL: https://repositori.urv.cat/ca/proteccio-de-dades/
    Publication Type: Proceedings Paper
    Author, as appears in the article.: Clement, P; Llobet, E; Lucat, C; Debeda, H
    licence for use: https://creativecommons.org/licenses/by/3.0/es/
    Thematic Areas: Química, Odontología, Medicina ii, Medicina i, Materiais, Interdisciplinar, General engineering, Farmacia, Engineering (miscellaneous), Engineering (all), Engenharias iv, Engenharias iii, Engenharias ii, Enfermagem, Ciências biológicas iii, Ciências biológicas ii, Ciências biológicas i, Ciências ambientais, Ciência de alimentos, Biotecnología, Astronomia / física, Arquitetura, urbanismo e design, Arquitetura e urbanismo
    Author's mail: eduard.llobet@urv.cat
  • Keywords:

    Piezoelectric cantilever
    Double transduction
    Cnts
    Chemical gas sensor
    Benzene
    31-longitudinal mode
    Engineering (Miscellaneous)
    Química
    Odontología
    Medicina ii
    Medicina i
    Materiais
    Interdisciplinar
    General engineering
    Farmacia
    Engineering (all)
    Engenharias iv
    Engenharias iii
    Engenharias ii
    Enfermagem
    Ciências biológicas iii
    Ciências biológicas ii
    Ciências biológicas i
    Ciências ambientais
    Ciência de alimentos
    Biotecnología
    Astronomia / física
    Arquitetura
    urbanismo e design
    Arquitetura e urbanismo
  • Documents:

  • Cerca a google

    Search to google scholar