Articles producció científica> Enginyeria Electrònica, Elèctrica i Automàtica

Use of a CNT-coated piezoelectric cantilever with double transduction as a gas sensor for benzene detection at room temperature

  • Identification data

    Identifier: imarina:5609693
    Authors:
    Clement, PLlobet, ELucat, CDebeda, H
    Abstract:
    © 2014 The Authors. Published by Elsevier Ltd. In this work, we propose to use a screen-printed piezoelectric cantilever with double transduction. Indeed, the piezoelectric cantilever is used as a resonant type sensor coated with carbon nanotubes (CNTs) as sensitive layer. Then, the resistance of CNTs is measured in static mode in parallel thanks to a modification of the cantilever top electrode. The combination of the CNTs equilibrium conductivity measurement and the resonance frequency shift of the 31-longitudinal mode allows the use of this device as a chemical gas sensor for benzene detection. The responses towards benzene concentrations under different relative humidity backgrounds are discussed.
  • Others:

    Author, as appears in the article.: Clement, P; Llobet, E; Lucat, C; Debeda, H
    Department: Enginyeria Electrònica, Elèctrica i Automàtica
    URV's Author/s: Llobet Valero, Eduard
    Keywords: Piezoelectric cantilever Double transduction Cnts Chemical gas sensor Benzene 31-longitudinal mode
    Abstract: © 2014 The Authors. Published by Elsevier Ltd. In this work, we propose to use a screen-printed piezoelectric cantilever with double transduction. Indeed, the piezoelectric cantilever is used as a resonant type sensor coated with carbon nanotubes (CNTs) as sensitive layer. Then, the resistance of CNTs is measured in static mode in parallel thanks to a modification of the cantilever top electrode. The combination of the CNTs equilibrium conductivity measurement and the resonance frequency shift of the 31-longitudinal mode allows the use of this device as a chemical gas sensor for benzene detection. The responses towards benzene concentrations under different relative humidity backgrounds are discussed.
    Thematic Areas: Química Odontología Medicina ii Medicina i Materiais Interdisciplinar General engineering Farmacia Engineering (miscellaneous) Engineering (all) Engenharias iv Engenharias iii Engenharias ii Enfermagem Ciências biológicas iii Ciências biológicas ii Ciências biológicas i Ciências ambientais Ciência de alimentos Biotecnología Astronomia / física Arquitetura, urbanismo e design Arquitetura e urbanismo
    licence for use: https://creativecommons.org/licenses/by/3.0/es/
    Author's mail: eduard.llobet@urv.cat
    Author identifier: 0000-0001-6164-4342
    Record's date: 2024-10-12
    Papper version: info:eu-repo/semantics/publishedVersion
    Licence document URL: https://repositori.urv.cat/ca/proteccio-de-dades/
    Papper original source: Procedia Engineering. 87 708-711
    APA: Clement, P; Llobet, E; Lucat, C; Debeda, H (2014). Use of a CNT-coated piezoelectric cantilever with double transduction as a gas sensor for benzene detection at room temperature. Amsterdam: Elsevier
    Entity: Universitat Rovira i Virgili
    Journal publication year: 2014
    Publication Type: Proceedings Paper
  • Keywords:

    Engineering (Miscellaneous)
    Piezoelectric cantilever
    Double transduction
    Cnts
    Chemical gas sensor
    Benzene
    31-longitudinal mode
    Química
    Odontología
    Medicina ii
    Medicina i
    Materiais
    Interdisciplinar
    General engineering
    Farmacia
    Engineering (miscellaneous)
    Engineering (all)
    Engenharias iv
    Engenharias iii
    Engenharias ii
    Enfermagem
    Ciências biológicas iii
    Ciências biológicas ii
    Ciências biológicas i
    Ciências ambientais
    Ciência de alimentos
    Biotecnología
    Astronomia / física
    Arquitetura, urbanismo e design
    Arquitetura e urbanismo
  • Documents:

  • Cerca a google

    Search to google scholar