Articles producció científica> Química Analítica i Química Orgànica

Enhanced Potentiometric Detection of Hydrogen Peroxide Using a Platinum Electrode Coated with Nafion

  • Datos identificativos

    Identificador: imarina:5131270
    Autores:
    Parrilla MCánovas RAndrade FJ
    Resumen:
    The potentiometric response to hydrogen peroxide of a platinum electrode coated with a layer of Nafion is presented. The results show that the Nafion membrane acts as an effective permselective barrier, thus significantly reducing the response to some redox active species, such as ascorbate. Even more interesting, these coated electrodes show a significantly enhanced sensitivity to hydrogen peroxide (H2O2) when the measurements are performed in solutions of high ionic strength. The influence of pH, ionic strength and supporting electrolyte on this enhancement are presented. Under optimized conditions these coated electrodes show a linear dependence with the logarithm of the concentration of H2O2, with sensitivities of −125.1±5.9 mV decade−1 (several times higher than the bare electrodes) and a linear range that spans from 10−5 M to 10−3 M of H2O2. Preliminary studies suggest that the coupling between the redox potential on the Pt electrode and the Donnan potential of the membrane plays a role on this enhancement. Considering this improved sensitivity, selectivity, stability and linear ranges, this system shows promise as a future platform to build enzyme-based potentiometric biosensors.
  • Otros:

    Autor según el artículo: Parrilla M; Cánovas R; Andrade FJ
    Departamento: Química Analítica i Química Orgànica
    e-ISSN: 1521-4109
    Autor/es de la URV: Andrade, Francisco Javier
    Palabras clave: Potentiometric sensors Nafion ion-exchange membrane Hydrogen peroxide Donnan potential
    Resumen: The potentiometric response to hydrogen peroxide of a platinum electrode coated with a layer of Nafion is presented. The results show that the Nafion membrane acts as an effective permselective barrier, thus significantly reducing the response to some redox active species, such as ascorbate. Even more interesting, these coated electrodes show a significantly enhanced sensitivity to hydrogen peroxide (H2O2) when the measurements are performed in solutions of high ionic strength. The influence of pH, ionic strength and supporting electrolyte on this enhancement are presented. Under optimized conditions these coated electrodes show a linear dependence with the logarithm of the concentration of H2O2, with sensitivities of −125.1±5.9 mV decade−1 (several times higher than the bare electrodes) and a linear range that spans from 10−5 M to 10−3 M of H2O2. Preliminary studies suggest that the coupling between the redox potential on the Pt electrode and the Donnan potential of the membrane plays a role on this enhancement. Considering this improved sensitivity, selectivity, stability and linear ranges, this system shows promise as a future platform to build enzyme-based potentiometric biosensors.
    Áreas temáticas: Saúde coletiva Química Psicología Medicina ii Medicina i Materiais Interdisciplinar Geociências Farmacia Engenharias iii Engenharias ii Electrochemistry Ciências biológicas ii Ciências biológicas i Ciências ambientais Ciências agrárias i Chemistry, analytical Biotecnología Biodiversidade Astronomia / física Analytical chemistry
    Acceso a la licencia de uso: https://creativecommons.org/licenses/by/3.0/es/
    Direcció de correo del autor: franciscojavier.andrade@urv.cat
    Identificador del autor: 0000-0003-1199-2837
    Fecha de alta del registro: 2024-09-07
    Versión del articulo depositado: info:eu-repo/semantics/acceptedVersion
    URL Documento de licencia: https://repositori.urv.cat/ca/proteccio-de-dades/
    Referencia al articulo segun fuente origial: Electroanalysis. 29 (1): 223-230
    Referencia de l'ítem segons les normes APA: Parrilla M; Cánovas R; Andrade FJ (2017). Enhanced Potentiometric Detection of Hydrogen Peroxide Using a Platinum Electrode Coated with Nafion. Electroanalysis, 29(1), 223-230. DOI: 10.1002/elan.201600403
    Entidad: Universitat Rovira i Virgili
    Año de publicación de la revista: 2017
    Tipo de publicación: Journal Publications
  • Palabras clave:

    Analytical Chemistry,Chemistry, Analytical,Electrochemistry
    Potentiometric sensors
    Nafion ion-exchange membrane
    Hydrogen peroxide
    Donnan potential
    Saúde coletiva
    Química
    Psicología
    Medicina ii
    Medicina i
    Materiais
    Interdisciplinar
    Geociências
    Farmacia
    Engenharias iii
    Engenharias ii
    Electrochemistry
    Ciências biológicas ii
    Ciências biológicas i
    Ciências ambientais
    Ciências agrárias i
    Chemistry, analytical
    Biotecnología
    Biodiversidade
    Astronomia / física
    Analytical chemistry
  • Documentos:

  • Cerca a google

    Search to google scholar