Articles producció científica> Enginyeria Electrònica, Elèctrica i Automàtica

SIMULATED AND EXPERIMENTAL INVESTIGATION OF MICROWAVE IMAGING USING UWB

  • Datos identificativos

    Identificador: imarina:6178113
    Autores:
    Lazaro, A.Girbau, D.Villarino, R.
    Resumen:
    Microwave breast tumour detection is a non-invasive technique that uses non ionizing radiation. Microwave imaging has the potential to achieve early detection of breast cancer due to the high specificity and the large difference in electrical properties of the malignant tissue when compared to normal breast tissue. This paper studies the feasibility of using UWB signals for breast imaging. Simulated results using Finite-Difference Time-Domain (FDTD) Method will be presented. A sensibility study of the variations in the breast relative dielectric permittivity and of the variations of the skin-surface contour is also provided. A working prototype for microwave imaging is developed using a conventional Vector Network Analyzer (VNA) with the time processing capability.
  • Otros:

    Autor según el artículo: Lazaro, A.; Girbau, D.; Villarino, R.;
    Departamento: Enginyeria Electrònica, Elèctrica i Automàtica
    Autor/es de la URV: Girbau Sala, David / Lázaro Guillén, Antonio Ramon / Villarino Villarino, Ramón Maria
    Palabras clave: Uwb antennas Uwb Tissue Reflection method Radar Probes Microwave tomography Breast cancer Breast Antenna
    Resumen: Microwave breast tumour detection is a non-invasive technique that uses non ionizing radiation. Microwave imaging has the potential to achieve early detection of breast cancer due to the high specificity and the large difference in electrical properties of the malignant tissue when compared to normal breast tissue. This paper studies the feasibility of using UWB signals for breast imaging. Simulated results using Finite-Difference Time-Domain (FDTD) Method will be presented. A sensibility study of the variations in the breast relative dielectric permittivity and of the variations of the skin-surface contour is also provided. A working prototype for microwave imaging is developed using a conventional Vector Network Analyzer (VNA) with the time processing capability.
    Áreas temáticas: Telecommunications Physics, applied Engineering, electrical & electronic Engenharias iii
    Acceso a la licencia de uso: https://creativecommons.org/licenses/by/3.0/es/
    ISSN: 15598985
    Direcció de correo del autor: antonioramon.lazaro@urv.cat david.girbau@urv.cat ramon.villarino@urv.cat
    Identificador del autor: 0000-0003-3160-5777 0000-0001-7995-5536 0000-0001-9692-8943
    Fecha de alta del registro: 2024-10-26
    Versión del articulo depositado: info:eu-repo/semantics/publishedVersion
    URL Documento de licencia: https://repositori.urv.cat/ca/proteccio-de-dades/
    Referencia al articulo segun fuente origial: Progress In Electromagnetics Research-Pier. 94 263-280
    Referencia de l'ítem segons les normes APA: Lazaro, A.; Girbau, D.; Villarino, R.; (2009). SIMULATED AND EXPERIMENTAL INVESTIGATION OF MICROWAVE IMAGING USING UWB. Progress In Electromagnetics Research-Pier, 94(), 263-280. DOI: 10.2528/PIER09061004
    Entidad: Universitat Rovira i Virgili
    Año de publicación de la revista: 2009
    Tipo de publicación: Journal Publications
  • Palabras clave:

    Engineering, Electrical & Electronic,Physics, Applied,Telecommunications
    Uwb antennas
    Uwb
    Tissue
    Reflection method
    Radar
    Probes
    Microwave tomography
    Breast cancer
    Breast
    Antenna
    Telecommunications
    Physics, applied
    Engineering, electrical & electronic
    Engenharias iii
  • Documentos:

  • Cerca a google

    Search to google scholar