Articles producció científicaCiències Mèdiques Bàsiques

Implementation of gamma-ray spectrometry in two real-time water monitors using NaI(Tl) scintillation detectors

  • Datos identificativos

    Identificador:  imarina:6387417
    Autores:  Casanovas, R; Morant, J J; Salvado, M
    Resumen:
    In this study, the implementation of gamma-ray spectrometry in two real-time water monitors using 2. in.×2. in. NaI(Tl) scintillation detectors is described. These monitors collect the water from the river through a pump and it is analyzed in a vessel, which is shielded with Pb. The full calibration of the monitors was performed experimentally, except for the efficiency curve, which was set using validated Monte Carlo simulations with the EGS5 code system. After the calibration, the monitors permitted the identification and quantification of the involved isotopes in a possible radioactive increment and made it possible to discard possible leaks in the nuclear plants. As an example, a radiological increment during rain is used to show the advantages of gamma-ray spectrometry. To study the capabilities of the monitor, the minimum detectable activity concentrations for 131I, 137Cs and 40K are presented for different integration times. © 2013 Elsevier Ltd.
  • Otros:

    Referencia de l'ítem segons les normes APA: Casanovas, R; Morant, J J; Salvado, M (2013). Implementation of gamma-ray spectrometry in two real-time water monitors using NaI(Tl) scintillation detectors. APPLIED RADIATION AND ISOTOPES, 80(), 49-55. DOI: 10.1016/j.apradiso.2013.06.003
    Referencia al articulo segun fuente origial: APPLIED RADIATION AND ISOTOPES. 80 49-55
    DOI del artículo: 10.1016/j.apradiso.2013.06.003
    Año de publicación de la revista: 2013-10-01
    Entidad: Universitat Rovira i Virgili
    Versión del articulo depositado: info:eu-repo/semantics/acceptedVersion
    Fecha de alta del registro: 2026-05-16
    Autor/es de la URV: Casanovas Alegre, Ramon / Morant Echevarne, Juan José / Salvadó Artells, Marçal / SALVADÓ USACH, MARIA TERESA
    Departamento: Ciències Mèdiques Bàsiques
    URL Documento de licencia: https://repositori.urv.cat/ca/proteccio-de-dades/
    Tipo de publicación: Journal Publications
    ISSN: 09698043
    Autor según el artículo: Casanovas, R; Morant, J J; Salvado, M
    Grupo de investigación: Física i Cristal·lografia de Materials
    Áreas temáticas: Radiology, nuclear medicine & medical imaging, Radiation, Nuclear science & technology, Engenharias ii, Chemistry, inorganic & nuclear, Administração pública e de empresas, ciências contábeis e turismo
    Direcció de correo del autor: m.salvado@urv.cat, m.salvado@urv.cat, juanjose.morant@urv.cat, juanjose.morant@urv.cat, juanjose.morant@urv.cat, juanjose.morant@urv.cat
  • Palabras clave:

    Scintillation gamma-ray spectrometry
    Nai(tl)
    Monte carlo simulation
    Efficiency calculation
    Clean water and sanitation
    Chemistry
    Inorganic & Nuclear
    Nuclear Science & Technology
    Radiation
    Radiology
    Nuclear Medicine & Medical Imaging
    Engenharias ii
    Administração pública e de empresas
    ciências contábeis e turismo
  • Documentos:

  • Cerca a google

    Search to google scholar