Autor según el artículo: Suazo, Mario; Herrero, Joan; Fortuny, Gerard; Puigjaner, Dolors; Lopez, Josep M.;
Departamento: Enginyeria Química Enginyeria Informàtica i Matemàtiques
Autor/es de la URV: Fortuny Anguera, Gerard / Herrero Sabartés, Juan / López Besora, Josep Maria / Puigjaner Riba, Maria Dolores / Suazo Euceda, Mario José
Palabras clave: Thoracic response Thoracic compressions Stiffness Model Hospital cardiac-arrest Hand Force Finite element simulation Depth Ct Compression point Chest compression Cardiopulmonary resuscitation Biomechanical response Age
Resumen: The biomechanical response of a human rib cage to cardiopulmonary resuscitation maneuvers was investigated by means of finite element simulations. We analyzed the effect of the location where the force was applied on the achieved compression depths and stress levels experienced by the breastbone and ribs. For compression locations on the breastbone, a caudal shift of the application area toward the breastbone tip resulted in a 17% reduction of the force required to achieve a target 5 cm compression depth. We found that the use of compression regions located on the costal cartilages would involve higher risk of rib fractures.
Áreas temáticas: Software Molecular biology Modeling and simulation Medicina ii Medicina i Mathematics, interdisciplinary applications Mathematical & computational biology Interdisciplinar Engineering, biomedical Engenharias iii Engenharias i Educação física Computational theory and mathematics Ciências biológicas ii Ciência da computação Biomedical engineering Applied mathematics
Acceso a la licencia de uso: https://creativecommons.org/licenses/by/3.0/es/
Direcció de correo del autor: gerard.fortuny@urv.cat dolors.puigjaner@urv.cat joan.herrero@urv.cat josep.m.lopez@urv.cat
Identificador del autor: 0000-0002-2500-7386 0000-0001-5251-2022 0000-0001-8501-1187 0000-0001-7541-8936
Fecha de alta del registro: 2024-09-07
Versión del articulo depositado: info:eu-repo/semantics/publishedVersion
Enlace a la fuente original: https://onlinelibrary.wiley.com/doi/full/10.1002/cnm.3585
URL Documento de licencia: https://repositori.urv.cat/ca/proteccio-de-dades/
Referencia al articulo segun fuente origial: International Journal For Numerical Methods In Biomedical Engineering. 38 (4): e3585-
Referencia de l'ítem segons les normes APA: Suazo, Mario; Herrero, Joan; Fortuny, Gerard; Puigjaner, Dolors; Lopez, Josep M.; (2022). Biomechanical response of human rib cage to cardiopulmonary resuscitation maneuvers: Effects of the compression location. International Journal For Numerical Methods In Biomedical Engineering, 38(4), e3585-. DOI: 10.1002/cnm.3585
DOI del artículo: 10.1002/cnm.3585
Entidad: Universitat Rovira i Virgili
Año de publicación de la revista: 2022
Tipo de publicación: Journal Publications