Autor según el artículo: Prieto, J; Ayou, DS; Coronas, A
Departamento: Enginyeria Mecànica
Autor/es de la URV: Ayou, Dereje Sendeku / Coronas Salcedo, Alberto / Prieto González, Juan
Palabras clave: Thermodynamic design-data H o/libr 2 Energy analysis Combined heating and cooling Absorption heat pump system saving performance proposal libr h2o efficiency combined desalination economics combined heating and cooling co2 absorption heat pump
Resumen: The aim of this study is to analyze the feasibility of the single-effect H2O/LiBr absorption heat pump cycle to produce combined heating and cooling. To achieve this, first, the main changes that the absorption cycle requires are described in comparison with the conventional single-effect absorption chiller. Then, the cycle’s operational limits in terms of temperature lift and LiBr crystallization are evaluated. In this sense, driving heat temperatures required for these applications range from 85 °C to 120 °C. The energy and exergy performance (in terms of cooling and heating capacities, cooling and heating coefficient of performance, and exergy coefficient of performance) of the cycle is theoretically studied for five different types of applications that require simultaneous heating and cooling: building air conditioning, a 4th generation district heating and cooling network, a sports center with an indoor swimming pool, a hybrid air conditioning system with an absorption heat pump and a desiccant evaporative cooling system, and simultaneous cooling and water purification application for coastal areas. The system performance in terms of the cooling coefficient of performance varies in the range of 0.812–0.842, in terms of heating coefficient of performance from 0.58 to 1.842, and in terms of exergy coefficient of performance from 0.451 to 0.667. The application with the highest exergy coefficient of performance is the 4th generation district heating and cooling network.
Áreas temáticas: Green & sustainable science & technology Global and planetary change Environmental sciences Environmental science (miscellaneous) Engineering, environmental
Acceso a la licencia de uso: https://creativecommons.org/licenses/by/3.0/es/
Direcció de correo del autor: derejesendeku.ayou@urv.cat alberto.coronas@urv.cat
Identificador del autor: 0000-0002-6109-3680
Fecha de alta del registro: 2024-08-03
Versión del articulo depositado: info:eu-repo/semantics/publishedVersion
Enlace a la fuente original: https://www.mdpi.com/2571-8797/5/1/4
URL Documento de licencia: https://repositori.urv.cat/ca/proteccio-de-dades/
Referencia al articulo segun fuente origial: Clean Technologies. 5 (1): 51-73
Referencia de l'ítem segons les normes APA: Prieto, J; Ayou, DS; Coronas, A (2023). A Novel H2O/LiBr Absorption Heat Pump with Condensation Heat Recovery for Combined Heating and Cooling Production: Energy Analysis for Different Applications. Clean Technologies, 5(1), 51-73. DOI: 10.3390/cleantechnol5010004
DOI del artículo: 10.3390/cleantechnol5010004
Entidad: Universitat Rovira i Virgili
Año de publicación de la revista: 2023
Tipo de publicación: Journal Publications