Treballs Fi de Màster> Enginyeria Electrònica, Elèctrica i Automàtica

Análisis y diseño de una aplicación informática de la norma UNE23585:2004 de Sistemas de Control de Temperatura y Evacuación de Humos para naves de una sola planta con actividad industrial

  • Dades identificatives

    Identificador: TFM:134
    Autors:
    Carrasco Noguer, Raquel Ariadna
  • Altres:

    Paraules clau: Control de fums, exutoris, contraincendis Smoke control, smoke ventilators, fire protection Control de humos, exutorios, contraincendios
    Títol en diferents idiomes: Anàlisi i disseny d'una aplicació informàtica de la norma UNE23585:2004 de Sistemes de Control de Temperatura i Evacuació de Fums per a naus d'una sola planta amb activitat industrial, inclosa la d'emmagatzematge Analysis and design of a Standard UNE23585:2004 software application of Temperature and Smoke Control Systems for industrial buildings of one floor, including storage Análisis y diseño de una aplicación informática de la norma UNE23585:2004 de Sistemas de Control de Temperatura y Evacuación de Humos para naves de una sola planta con actividad industrial, incluida la de almacenamiento
    Àrees temàtiques: Enginyeria química Chemical engineering Ingeniería química
    Confidencialitat: No
    Curs acadèmic: 2015-2016
    Estudiant: Carrasco Noguer, Raquel Ariadna
    Departament: Enginyeria Electrònica, Elèctrica i Automàtica
    Drets d'accés: info:eu-repo/semantics/openAccess
    Data de la defensa del treball: 2016-09-16
    Crèdits del TFM: 10
    Director del projecte: Turon Rodriguez, Carlos
    Resum: El humo es la principal causa de fallecimiento entre las víctimas de los incendios, convirtiendo a los sistemas de control y evacuación de humo en elementos fundamentales de cara a garantizar la seguridad de los ocupantes. Dentro de un edificio o establecimiento, el mayor peligro es la fácil propagación del humo por todos los recintos próximos no compartimentados adecuadamente y, por tanto, por aquellos medios o vías de evacuación que deberían estar en condiciones de permitir la libre circulación de los ocupantes de dicho edificio. La norma UNE 23585:2004, que define los requisitos, métodos de cálculo y diseño para proyectar dichos sistemas, es una norma muy extensa y en muchos aspectos de difícil comprensión. El presente trabajo analiza la norma incluyendo los mecanismos básicos en el desarrollo de un incendio y la producción de humos, la relación e influencia de los parámetros más importantes y la metodología de cálculo para edificios de una sola planta con actividad industrial y/o de almacenamiento. Finalmente se diseña una aplicación informática en la que se aplican, siguiendo las directrices de la citada normativa, los parámetros básicos para el cálculo del número de exutorios de extracción natural a instalar en la edificación industrial tipo, anteriormente definida Smoke is the leading cause of death among fire victims, making smoke and temperature control systems fundamental elements, in order to guarantee the safety of the occupants. Inside a building, the greatest danger is the easy spread of smoke for all the enclosures that are not properly distributed or separated. This fact can cause that fire evacuation routes are not in good condition to allow free evacuation of occupants in the building. The UNE 23585:2004 standard define the requirements, calculation and design methods, to project this type of systems. It is extensive and in many ways, difficult to understand so it needs certain time to be carefully studied. The present job analyzes this standard including the basic mechanisms in the development of a fire and smoke production. It evaluates the relationship and influence of the most important parameters and describes the calculation methodology for the case of a one floor building with industrial activity and/or storage. Finally it is designed a calculation software that uses the mentioned legislation to obtain basically, the required number of natural extraction smoke ventilators to protect the building in case of fire. El fum és la principal causa de mort entre les víctimes dels incendis, convertint als sistemes de control i evacuació de fums en elements fonamentals de cara a garantir la seguretat dels ocupants. Dins d’un edifici o establiment, el major perill és la fàcil propagació del fum per tots els recintes pròxims no compartimentats adequadament i per tant, per aquells medis o vies d’evacuació que haurien d’estar en condicions de permetre la lliure circulació dels ocupants en l’esmentat edifici. La norma UNE 25585:2004, que defineix els requisits, mètodes de càlcul i disseny per a projectar aquests sistemes, és una norma molt extensa y en molts aspectes de difícil comprensió. El present treball analitza la norma incloent els mecanismes bàsics en el desenvolupament d’un incendi i la producció de fums, la relació e influència dels paràmetres més importants i la metodologia de càlcul per a edificis d’una sola planta amb activitat industrial i/o d’emmagatzematge. Finalment es dissenya una aplicació informàtica en la que s’apliquen, seguint les directrius de la citada normativa, els paràmetres bàsics per al càlcul del número d’exutoris d’extracció natural a instal·lar en la edificació industrial tipus, anteriorment definida
    Matèria: Edificis industrials -- Mesures de seguretat
    Entitat: Universitat Rovira i Virgili (URV)
    Idioma: Castellà
    Ensenyament(s): Enginyeria Industrial
    Títol en la llengua original: Análisis y diseño de una aplicación informática de la norma UNE23585:2004 de Sistemas de Control de Temperatura y Evacuación de Humos para naves de una sola planta con actividad industrial, incluida la de almacenamiento
    Data d'alta al repositori: 2016-10-17
  • Paraules clau:

    Enginyeria química
    Chemical engineering
    Ingeniería química
    Edificis industrials -- Mesures de seguretat
  • Documents:

  • Cerca a google

    Search to google scholar